Compatible with conditions MANUFACTURER SOURCE

SE10K-RWB48 + SolarEdge BAT-05K48: compatible with conditions

The source supports this combination only under stated conditions.

Inverter
SolarEdge
SE10K-RWB48
AU
+
Battery
SolarEdge
BAT-05K48
Exact listed model/label
Verdict
Compatible with conditions
Communication
RS485 / Leader inverter connects to Backup Interface Three Phase via RS485.
Evidence scope
Exact model / label
Conditions
5 source-backed
Source date
2025-12
Manufacturer identity not independently resolved

Manufacturer identity is source-defined only. External entity mapping and model expansion are intentionally disabled.

Commissioning

Communication & inverter setup

Source supported
RS485
Backup Interface communication
Leader inverter connects to Backup Interface Three Phase via RS485.
Evidence
Version 1.1, December 2025, page 3
Source-listed setup
Before commissioning: These are source-listed setup values. Verify current manufacturer manuals and firmware before commissioning. The database does not designate a preferred method for this pair.
Source conditions

Conditions attached to this Pair

5 conditions
COMMUNICATION

Leader Home Hub inverter connects to Backup Interface Three Phase via RS485.

Version 1.1, December 2025
FIRMWARE

Specified follower configurations require SolarEdge SetApp firmware 4.21.xx or later.

Version 1.1, December 2025
INSTALLATION

A three-phase grid is required for backup operation.

Version 1.1, December 2025
INSTALLATION

Leader Home Hub Three Phase inverter must be connected to a compatible battery.

Version 1.1, December 2025
MARKET

AUS/NZ source scope applies; do not generalize to other markets.

Version 1.1, December 2025
How to read this page

Confirmed by this dataset

  • The verdict is derived from bound canonical entities, not fuzzy matching.
  • The communication/setup values shown are present in the cited source.

Not assumed

  • Missing pinout, firmware, cable or DIP data does not mean none is required.
  • A source-listed setup value is not automatically treated as a manufacturer-recommended method.
Traceability

Source evidence

1 source row
Version 1.1, December 20252025-12 Pages 3
View raw source evidence
Version 1.1, December 2025 · 2025-12 · page 3 · source row 1
{"inverter":"SE10K-RWB48","battery":"BAT-05K48","market_code":"AU","source":"Compatible batteries section / Overview"}
Exact-pair interpretation

Why SE10K-RWB48 + SolarEdge BAT-05K48 is listed this way

Compatibility basis

This published page binds the exact inverter SE10K-RWB48 to the exact battery model SolarEdge BAT-05K48. The current database resolution is CONDITIONAL under SOLAREDGE_AU_HOME_HUB_2025. The verdict is produced from the stored manufacturer-source relationship for these canonical entities, not from fuzzy search similarity or a generic voltage-class assumption.

Communication setup recorded for this Pair

For this exact Pair, the database stores one source-supported communication path.

  • RS485 — Backup Interface communication Leader inverter connects to Backup Interface Three Phase via RS485., source-listed in Version 1.1, December 2025 (2025-12), page 3. This is a source-supported setup value, not an independently inferred recommendation.

Evidence coverage

The result is backed by 1 page-level evidence record on page 3 of Version 1.1, December 2025 (2025-12).

No extra wiring, DIP-switch, firmware, cable, charge-limit, or pinout claim is created from absence or analogy.

The source attaches 5 explicit conditions to this Pair; the condition text is shown separately and is not generalized to other models.

Check another combination

Search by the model names you actually have

The search layer can handle aliases and fuzzy input; compatibility is checked only after the exact database entities are confirmed.

Open compatibility search
Technical safety note. This database summarizes source-backed compatibility information. Verify current manuals, firmware requirements, wiring, voltage class and commissioning instructions before installation or service work.